Model: | FTT-MDU16 |
---|---|
Min. Order: | 1 Piece/Pieces |
Payment Terms: | Paypal, L/C, T/T, WU |
Place of Origin: | Zhejiang, China (Mainland) |
Means of Transport: | Ocean, Air, Land |
Production Capacity: | 50000pcs/year |
Packing: | carton box |
Delivery Date: | in 1 week | Dimension: | 260*213*116 (mm) |
---|---|---|---|
Max Capacity: | 8 (SC / APC 1/8) | Derrick Installation Size: | 210*126*179 mm |
Into the Largest Cable Diameter (mm): | 12 | Working Temperature: | -40ºC ~ +85ºC |
Relative Humidity: | ≤85% (+30ºC) | Atmospheric Pressure: | 70KPa ~ 106Kpa |
Main Technical Datasheet Insertion Loss: | ≤ 0.15dB | UPC Return Loss: | ≥ 50dB |
APC Return Loss: | ≥ 60dB |
Description:
The equipment is used as a termination point for the feeder cable to connect with drop cable in FTTx communication network system.
The fiber splicing, splitting, and distribution can be done in this box, and meanwhile it provides solid protection and management for the FTTx network building.
Features:
● Total enclosed structure.
● Material: PC+ABS, wet-proof, water-proof, dust-proof, anti-aging, protection level up to IP65.
● Clamping for feeder cable and drop cable, fiber splicing, fixation, storage, distribution...etc all in one.
● Cable, pigtails, and patch cords are running through their own paths without disturbing each other, micro type PLC splitter installation, easy maintenance.
● Distribution panel can be flipped up, feeder cable can be placed by expression port, easy for maintenance and installation.
● Box can be installed by the way of wall-mounted or poled-mounted, suitable for both indoor and outdoor use.
Specification:
● Environmental requirement
Working temperature: -40ºC~ +85ºC
Relative humidity: ≤85% (+30ºC)
Atmospheric pressure: 70KPa~106Kpa
● Main technical datasheet Insertion loss: ≤0.15dB
UPC return loss: ≥50dB
APC return loss: ≥60dB
● Thunder-proof technical datasheet
The insulation resistance between the grounding device and the metal parts of the box is no less than 2ᄡ104MÙ/500V (DC); IR≥2ᄡ104MÙ/500V.
The voltage resistance between the grounding device, and the box and its metal parts is no less than 3000V (DC)/min, no puncture, no flashover; U≥3000V
Configuration Table
Table 1 Model and configuration
Model | Size (Pic 1) A*B*C | Max Capacity: | Installation Size: | Hang a to install size (pic 2) D*J | Into the largest cable diameter(mm) | |
FTT-MDU16-B-1 | 260*213*116 (mm) | 8 (SC / APC 1/8) | 210*126*179 mm | 21*52 | 12 | IN: red NIX:green |
FTT-MDU16-B-2 | 260*213*116 (mm) | 3 (SC / APC 1/4) 8 (SC / APC 1/8) | 210*126*179 mm | 21*52 | 12 | IN: red NIX:green |
Category: Indoor Fiber Optical Termination Box
Related Category: Outdoor Fiber Optical Termination Box